6 resultados para High Pressure Liquid

em Universidade Complutense de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Amorphous silicon thin films were deposited using the high pressure sputtering (HPS) technique to study the influence of deposition parameters on film composition, presence of impurities, atomic bonding characteristics and optical properties. An optical emission spectroscopy (OES) system has been used to identify the different species present in the plasma in order to obtain appropriate conditions to deposit high purity films. Composition measurements in agreement with the OES information showed impurities which critically depend on the deposition rate and on the gas pressure. We prove that films deposited at the highest RF power and 3.4 × 10^−2 mbar, exhibit properties as good as the ones of the films deposited by other more standard techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The demand of highest quality foods in terms of taste and their properties preservation without the use of additives is constantly increasing. Consequently, new approaches to food processing have been developed, as for example high-pressure technology which has proven to be very valuable because it allows to maintain good properties of food like some vitamins and, at the same time, to reduce some undesirable bacteria. This technology avoids the use of high temperatures during the process (not like Pasteurization), which may have adverse effect on some nutritional properties of the food, its flavour, etc. The models for some enzymatic inactivations, which depend on the pressure and temperature profiles are presented. This work deals with the optimization of the inactivation of certain enzymes when high pressure treatment on food processing is applied. The optimization algorithms will minimize the inactivation not only of a certain isolated enzyme but also to several enzymes that can be involved simultaneously in the high-pressure process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose.: To analyze the levels of diadenosine tetraphosphate (Ap4A) and diadenosine pentaphosphate (Ap5A) in tears of subjects with Sjögren syndrome and to compare them with those in a control group. Methods.: Twelve subjects with a diagnosis of Sjögren syndrome and 20 healthy control subjects were invited to participate in the present study. Schirmer strips were used to measure tear secretion (Schirmer I test) and to collect tears. Ap4A and Ap5A were measured by high-pressure liquid chromatography (HPLC), and a dry eye questionnaire (DEQ) was used to evaluate dry eye symptomatology. Results.: The mean concentrations of Ap4A and Ap5A in the Sjögren syndrome group were 2.54 ± 1.02 and 26.13 ± 6.95 μM, respectively. This group of patients was divided in two subgroups: four patients with normal tear production and eight patients with low tear production. Concentrations of Ap4A, and Ap5A in patients with normal tear production (Schirmer test result, 12.3 ± 1.2 mm) were 0.47 ± 0.20 and 8.03 ± 3.27 μM, respectively. In the patients with low tear production (Schirmer test result, 1.0 ± 0.3 mm), the concentrations were 4.09 ± 1.36 and 39.51 ± 8.46 μM, respectively and in the control group, 0.13 ± 0.03 and 0.04 ± 0.02 μM, respectively. Conclusions.: Patients with Sjögren syndrome have abnormally elevated concentrations of diadenosine polyphosphates, indicating that these compounds could be used in the diagnosis of this disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose To evaluate the possible use of soft contact lenses (CL) to improve the secretagogue role of diadenosine tetraphosphate (Ap4A) promoting tear secretion. Methods Two conventional hydrogel CL (Omafilcon A and Ocufilcon D) and two silicone hydrogel (SiH) CL (Comfilcon A and Balafilcon A) were used. Ap4A was loaded into the lenses by soaking in a 1 mM Ap4A solution during 12 h. In vitro experiments were performed by placing the lenses in multi-wells during 2 h containing 1 ml of ultrapure water. 100 μl aliquots were taken at time zero and every minute for the first 10 min, and then every 15 min. In vivo experiments were performed in New Zealand rabbits and both the dinucleotide release from SiH and tear secretion were measured by means of Schirmer strips and high-pressure liquid chromatography (HPLC) analysis. Results Ap4A in vitro release experiments in hydrogel CL presented a release time 50 (RT50) of 3.9 ± 0.2 min and 3.1 ± 0.1 min for the non-ionic and the ionic CL, respectively. SiH CL released also Ap4A with RT50 values of 5.1 ± 0.1 min for the non-ionic and 2.7 ± 0.1 min for the ionic CL. In vivo experiments with SiH CL showed RT50 values of 9.3 ± 0.2 min and 8.5 ± 0.2 min for the non-ionic and the ionic respectively. The non-ionic lens Ap4A release was able to induce tear secretion above baseline tear levels for almost 360 min. Conclusion The delivery of Ap4A is slower and the effect lasts longer with non-ionic lenses than ionic lenses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To analyze the levels of the diadenosine polyphosphates Ap4A and Ap5A in tears, in a set of control subjects and in groups of symptomatic and nonsymptomatic persons with dry eye. Methods. Ninety-seven subjects participated in the study. The subjects were divided into five experimental groups: control subjects; symptomatic patients with normal tear secretion; symptomatic patients with low tear secretion; forced blink; and corneal mechanical stimulation provided by a gas esthesiometer. The Schirmer I test was used to measure and collect tear secretions from each subject. All samples were processed by high pressure liquid chromatography (HPLC) and their Ap4A and Ap5A levels determined. Results. The levels of Ap4A and Ap5A in tears were greater in all symptomatic patients than in control subjects, especially in symptomatic subjects with low tear secretion. Within the symptomatic subjects with normal tear secretion, significant differences in concentrations of Ap4A and Ap5A were found between men and women. In the forced blink experiments, concentrations of the Ap4A and Ap5A rose with increasing blink frequency. When the cornea was mechanically stimulated, the levels of Ap4A and Ap5A rose significantly during both moderate and high-flow rate tests. Conclusions. The increased levels of Ap4A and Ap5A in tears of patients with dry eye allow these dinucleotides to be used as objective biomarkers in dry eye conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose.: To evaluate the levels of dinucleotides diadenosine tetraphosphate (Ap4A) and diadenosine pentaphosphate (Ap5A) in tears of patients wearing rigid gas permeable (RGP) contact lenses on a daily wear basis and of patients wearing reverse-geometry RGP lenses overnight for orthokeratology treatment. Methods.: Twenty-two young volunteers (10 females, 12 males; 23.47 ± 4.49 years) were fitted with an alignment-fit RGP lens (paflufocon B) for a month, and after a 15-day washout period they were fitted with reverse-geometry RGP lenses for corneal reshaping (paflufocon D) for another month. During each period, tears were collected at baseline day 1, 7, 15, and 28. Ap4A and Ap5A were measured by high-pressure liquid chromatography (HPLC). Additionally, corneal staining, break-up time (BUT), Schirmer test, and dryness symptoms were evaluated. Results.: Ap4A concentrations increased significantly from baseline during the whole period of daily wear of RGP lenses (P < 0.001); concentration was also significantly higher than in the orthokeratology group, which remained at baseline levels during the study period except at day 1 (P < 0.001) and day 28 (P = 0.041). While BUT and Schirmer remained unchanged in both groups, discomfort and dryness were significantly increased during alignment-fit RGP daily wear but not during the orthokeratology period. Conclusions.: Daily wear of RGP lenses increased the levels of Ap4A due to mechanical stimulation by blinking of the corneal epithelium, and this is associated with discomfort. Also, orthokeratology did not produce symptoms or signs of ocular dryness, which could be a potential advantage over soft contact lenses in terms of contact lens-induced dryness.